4-22
4.12.5 Blurred background
Symptom: Copies show a gray or dark background.
ABCDE
ABCDE
ABCDE
ABCDE
ABCDE
Poor development
Replace the High Voltage Unit.
Replace the Main Control PCB.
Replace the Toner Cartridge.
Replace the Drum Cartridge.
4.12.6 Uneven print density
B
B
B
B
B
A
A
A
A
A
CDE
CDE
CDE
CDE
CDE
Symptom: Image graduates from dark to light across page.
Poor development
The drum cartridge or toner cartridge may be not installed correctly. Install
each cartridge correctly.
Replace the Toner cartridge
Replace the High Voltage Unit.
Clean the LED print head.
Defective Drum
If the drum surface for moisture condensation found, leave drum in unit with
power on to dry.
Replace the Drum Cartridge.
Poor image transfer
Replace the Image Transfer Unit.
Replace the High Voltage Unit.
Replace the Main Control PCB.